Shunt Trip Breaker TREF2-125 Earth Leakage Circuit Breaker ELCB 125F/3P 15A-125A
Shunt Trip Breaker TREF2-125 Earth Leakage Circuit Breaker ELCB 125F/3P 15A-125A
ELCB TREM Series
Mould Case Circuit Breaker with Earth Leakage Protection
A shunt-trip breaker, in addition to the internal instantaneous overcurrent and time-overcurrent protective functions, has an externally powered solenoid that will trip the breaker when energized. This is normally tied to a safety interlock system that will shut power off to the affected equipment when, for example, a protective cover is opened or removed. A limit switch or other similar device will be used to detect if the cover is in place or not. It is held open by the cover. If the switch closes, the breaker is tripped and the machine is rendered electrically safe.
For bulk purchasing, please email to : info@electric-b2c.com
Standard
TRM series circuit breaker and auxiliaries comply with the following international standard:
1.IEC/EN 60947-1
Low-voltage switchgear and controlgear-part 1: General rules;
2.IEC/EN 60947-2
Low-voltage switchgear and controlgear-part 2: Circuit breakers;
TRM series MCCB(Standard use environment for TRM series MCCB)
1. Ambient temperature: Within the range of -5ºC--+55ºC(However, when the temperature exceed 40ºC,it should be considered to reduce the capacity to use);
2. Relative humidity: Within the range of 45%--85%;
3. Altitude: 2000m or less(However, if it exceeds 1000m, atmosphere correction through humidity test and withstand voltage test can be considered);
4. Atmosphere where excessive steam, oil steam, smoke, dust, salt and other corrosive materials do not exist
3 phase elcb price,elcb 100a,100 amp elcb price,shunt trip breaker,shunt trip circuit breaker
CLASSIFICATION:
ACCORDING TO THE POLES: 2-POLES, 3-POLES
ACCORDING TO THE BREAKING CAPACITY: S-TYPE, H-TYPE
ACCORDING TO THE RATED CURRENT: FIX TYPE, ADJUSTABLE TYPE(08IN-1.0IN)
ACCORDING TO THE TRIP ACTION TIME: FIX TYPE, ADJUSTABLE TYPE(0.1S/0.3S/0.5S OR 0.45S/1.0S/2.0S)
ACCORDING TO THE RATED RESIDUAL CURRENT: FIX TYPE, ADJUSTABLE TYPE(30MA/100MA/300MA/500MA
Technical data table:
Ampere frame size | TREF2(125A) | ||||||
Breaking capacity code | S | H | |||||
Product code and poles | 2P | 3P | 4P | 2P | 3P | 4P | |
TREF2-S2 | TREF2-S2 | TREF2-S2 | TREF2-H2 | TRMF2-H3 | TRMF2-H4 | ||
Protective function | Over load & Short circuit & Ground fault | ||||||
Rated current, In(A) | 15, 20, 30, 40, 50, 60, 75, 80, 100, 125 | ||||||
Rated residual current | Operating, IΔn(mA) | 30, 50, 100, 200, 300, 500 | |||||
Non-operating, IΔno(mA) | 15, 25, 50, 100, 150, 250 | ||||||
Adjustable part | Rated current setting(0.8In-1.0In) | √ | √ | ||||
Lockup device for operating handle | - | √ | √ | - | √ | √ | |
Residual current, IΔn | 30mA/100mA/300mA/500mA | ||||||
Trip action time | 0.1s/0.3s/0.5s | ||||||
Rated operational voltage, Ue(V), AC 50/60 Hz | 240/415 | ||||||
Rated insulation voltage, Ui(V) | 1000 | ||||||
Rated impulse withstand voltage, Uimp(kV) | 8 | ||||||
Residual current off-time at IΔn ,Sec (s) | 0.1 | ||||||
Standard | Conformity with IEC/EN 60947-2 | ||||||
Rated frequency(Hz) | 50/60 | ||||||
Rated short-circuit breaking capacity, Icu(kA) | |||||||
AC | 240V | 35 | 50 | ||||
415V | 18 | 35 | |||||
Ics=% * Icu | 100% | ||||||
Mechanical life(circle) | 8500 | ||||||
Electrical life(circle) | 1500 | ||||||
Dimension: Length*Width*Height |
2-poles | 130*50*60 | |||||
3-poles | 130*75*60 | ||||||
4-poles | 130*100*60 |