Skip to product information
1 of 5

electrical center b2c

Shunt Trip Breaker TREF2-125 Earth Leakage Circuit Breaker ELCB 125F/3P 15A-125A

Regular price $47.40 USD
Regular price Sale price $47.40 USD
Sale Sold out
Shipping calculated at checkout.
Ampere
Built-in Accessories

Shunt Trip Breaker TREF2-125 Earth Leakage Circuit Breaker ELCB 125F/3P 15A-125A

ELCB TREM Series

Mould Case Circuit Breaker with Earth Leakage Protection

A shunt-trip breaker, in addition to the internal instantaneous overcurrent and time-overcurrent protective functions, has an externally powered solenoid that will trip the breaker when energized. This is normally tied to a safety interlock system that will shut power off to the affected equipment when, for example, a protective cover is opened or removed. A limit switch or other similar device will be used to detect if the cover is in place or not. It is held open by the cover. If the switch closes, the breaker is tripped and the machine is rendered electrically safe.

For bulk purchasing, please email to : info@electric-b2c.com


Standard
TRM series circuit breaker and auxiliaries comply with the following international standard:
1.IEC/EN 60947-1
Low-voltage switchgear and controlgear-part 1: General rules;
2.IEC/EN 60947-2
Low-voltage switchgear and controlgear-part 2: Circuit breakers;

TRM series MCCB(Standard use environment for TRM series MCCB)
1. Ambient temperature: Within the range of -5ºC--+55ºC(However, when the temperature exceed 40ºC,it should be considered to reduce the capacity to use);
2. Relative humidity: Within the range of 45%--85%;
3. Altitude: 2000m or less(However, if it exceeds 1000m, atmosphere correction through humidity test and withstand voltage test can be considered);
4. Atmosphere where excessive steam, oil steam, smoke, dust, salt and other corrosive materials do not exist 

3 phase elcb price,elcb 100a,100 amp elcb price,shunt trip breaker,shunt trip circuit breaker

CLASSIFICATION:
ACCORDING TO THE POLES:                                        2-POLES, 3-POLES
ACCORDING TO THE BREAKING CAPACITY:                       S-TYPE, H-TYPE
ACCORDING TO THE RATED CURRENT:                             FIX TYPE, ADJUSTABLE TYPE(08IN-1.0IN)
ACCORDING TO THE TRIP ACTION TIME:                           FIX TYPE, ADJUSTABLE TYPE(0.1S/0.3S/0.5S OR 0.45S/1.0S/2.0S)
ACCORDING TO THE RATED RESIDUAL CURRENT:                 FIX TYPE, ADJUSTABLE TYPE(30MA/100MA/300MA/500MA

mccb
Technical data table:
Ampere frame size TREF2(125A)
Breaking capacity code S H
Product code and poles 2P 3P 4P 2P 3P 4P
TREF2-S2 TREF2-S2 TREF2-S2 TREF2-H2 TRMF2-H3 TRMF2-H4
Protective function Over load & Short circuit & Ground fault
Rated current, In(A) 15, 20, 30, 40, 50, 60, 75, 80, 100, 125
Rated residual current Operating, IΔn(mA) 30, 50, 100, 200, 300, 500
Non-operating, IΔno(mA) 15, 25, 50, 100, 150, 250
Adjustable part Rated current setting(0.8In-1.0In)
Lockup device for operating handle - -
Residual current, IΔn 30mA/100mA/300mA/500mA
Trip action time 0.1s/0.3s/0.5s
Rated operational voltage, Ue(V), AC 50/60 Hz 240/415
Rated insulation voltage, Ui(V) 1000
Rated impulse withstand voltage, Uimp(kV) 8
Residual current off-time at IΔn ,Sec (s) 0.1
Standard Conformity with IEC/EN 60947-2
Rated frequency(Hz) 50/60
Rated short-circuit breaking capacity, Icu(kA)
AC 240V 35   50
415V 18   35
Ics=% * Icu 100%
Mechanical life(circle) 8500
Electrical life(circle) 1500
Dimension:
Length*Width*Height
2-poles 130*50*60
3-poles 130*75*60
4-poles 130*100*60
Built-in accessory:
mccb modular design
Built-out accessory:
mccb


Please contact Factory for bulk purchase, website: www.tranerelectric.com

 

 


Care Instructions

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)